logo

Break the Beam, the Robot Stops: Perimeter Guarding for an Automated EMC Test Cell

APREL needed a safety perimeter around a robotic EMC test cell, configurable to the room it ships into. We proved it on our own floor in Carp, then demonstrated it in their lab in Kanata, where it passed acceptance.

Smart Manufacturing

•Nov 28, 2026

2 minutes read

3 views

Application Spotlight #01 · Perimeter Guarding

The ask

APREL builds automated EMC test systems, with a robot that moves a probe around the device under test. When a cell like that ships to a customer's lab, the people working around it need a clear, reliable rule: if anyone steps into the robot's zone, the robot stops.

Every lab is different, so the guarding couldn't be a fixed cage. It had to fit the room it ended up in.

What we built

  • A configurable light-curtain perimeter. Safety light curtains and corner mirrors on free-standing posts. The number of corner mirrors sets how many sides are guarded, up to three mirrors for a full four-sided perimeter.
  • Clear status at a glance. A tower light and an illuminated reset button show the operator whether the zone is clear and armed, or whether a reset is needed.
  • One simple rule. Break the beam and the robot stops, through the robot controller's protective-stop input.

Proven on our floor first

Before anything shipped, we set up the full three-mirror perimeter in our facility in Carp, Ontario, and aligned it end to end. One lesson became a design rule: lock the corner mirrors at 45° and align the system by post position, plumb and height, rather than by turning the mirrors. It makes alignment faster and repeatable for whoever installs it next.

Accepted on site

We then brought the assembled system to APREL's lab in Kanata, demonstrated it running around the robot cell, and walked their installer through the alignment method. APREL ran the acceptance tests and signed off on the system.

Guarding a robot cell, or making one configurable for different rooms? Talk to our engineers.

Related Articles

Break the Beam, the Robot Stops: Perimeter Guarding for an Automated EMC Test Cell
Smart Manufacturing•Nov 28, 2026

Break the Beam, the Robot Stops: Perimeter Guarding for an Automated EMC Test Cell

APREL needed a safety perimeter around a robotic EMC test cell, configurable to the room it ships into. We proved it on our own floor in Carp, then demonstrated it in their lab in Kanata, where it passed acceptance.

2 min readRead more
Is Every Insert In? Proving Insert Verification on Real Parts
Smart Manufacturing•Nov 27, 2026

Is Every Insert In? Proving Insert Verification on Real Parts

An injection moulder needed to confirm every metal insert was in place on every part. We proved it on their own parts first: 15 insert locations, top and bottom views, a clear pass or fail at line speed.

2 min readRead more
Should This Be Automated? Five Questions We Ask First
Smart Manufacturing•Nov 27, 2026

Should This Be Automated? Five Questions We Ask First

Before we design anything, we work through five questions with your team: volume, variation, defining good, stability and proof. Every answer shapes the design, and none of them is a dealbreaker on its own.

2 min readRead more